Add to Cart
High Precision Lithium Battery Cell Battery External Short Circuit Tester
Product Name:Battery short-circuit testing machine
Product Model:GX-6055
Test purpose: This test simulates an external short circuit
Requirement: Short circuit of positive and negative terminals of the battery shall not cause fire or explosion
Test standard:
IEC 62133, UN38.3, UL 2054, UL 1642, QC/T 744-2006, QC/T 743-2006,
7. Technical Parameter:
Working voltage | AC 220V 50Hz-60Hz |
Impact voltage | AC 1kv/1.2-50μs(max)1min |
Maximum testing voltage | 100V~1000V |
Dc response time | ≤5μs |
Maximum short circuit current | 1000A |
The device interior resistance | 80±20mΩ |
Action time | Response time / release time ≯30ms |
Performance characteristic | Cold and voltage ≯66%Us Cold release voltage ≯30%Us,≮5%Us |
Operating Mode | Remote control within 7 meters without barrier |
Explosion-proof case material | Inner case: SUS# 304 stainless steel sheet Outer case: Cold-roll steel sheet with paint |
Cotrol Mode | PLC touch screen full-automatic control |
Voltage,temperature, current collection | External connected multi - channel data acquisition instrument or PLC data collection module, Channels are extended in Nx4 mode |
Explosion-proof temperature Range | RT + 10~200 ℃ |
Heat preservation material | Efficient compression glass wool or Rigid polyurethane foam cotton |
Temperature control accurcey | 0.1℃ |
Temperature uniformity | ± 2 ℃ |
Temperature luctuation | ± 0.5 ℃ |
Explosion inner box size | 500*500*500mm, 400*400*400mm, 500*600*500mm or customized |
Short circuit Mode | RT Short circuit high temperature short circuit short circuit protection high-low temperature short circuit |
Operating ambient temperature | temperature -10℃~100℃, humidity 10~90% no condensation |
Power | AC 220V± 10%, 50/60Hz, 380V ± 1% |
Gas consumption | 0.5~0.8MPa |