Add to Cart
Cells Or Batteries Temperature Cycling Test Chamber
Programmable Temperature CyclingTest Chamber (Rapid Temperature Change Test Chamber)
Model number: GX-3000-150LT
Standards Basis:
UL 1642 "lithium battery standard"
UL 2054 "Household and Commercial Battery Pack"
UN38.3 "Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria Part III"
MH / T 1052-2013 "Air Transport Lithium Battery Test Specification"
IEC62133-2012 "Safety requirements for batteries and accumulators containing alkaline or non-acidic electrolytes"
IEC 62281: 2004 "Safety Requirements for Lithium Batteries and Batteries in Transport"
IEC 60086: 2007 "Original battery Part 4 Safety requirements for lithium batteries"
Specification
Temperature range: -40°C ~ +150°C
Temperature control accuracy: ±0.01 °C
Temperature fluctuation: ≤±0.3°C
Temperature uniformity: ±1.5 °C (measured by the national measurement standard nine-point measurement method)
Temperature rise and fall: conversion between -40 and 75 °C is completed in 30 minutes (average temperature rise, non-linear no load)
Inner box size: 50×50×60 cm (the inner box space can be customized according to different customer requirements)
Outer box size: 80 × 165 × 140cm
Inner box material: SUS#304 first grade stainless steel
Insulation material: rigid foam (such as glass wool at 150 ° C)
Accessories: window, 2 adjustable upper and lower compartments, Ø50mm/Ø100mm1 hole for test hole, light inside the box,
Power: 3∮, AC380V±10%, 50Hz, 20A
Security system
Over temperature protector
Zero-crossing gate fluid power controller
Air-burning protection protector
Under phase reverse phase protection switch
Compressor high voltage protection switch
Compressor overheat protection switch
Compressor overcurrent protection switch
No fuse switch
Ceramic fast fuse
Line fuse and fully sheathed terminal
Buzzer
For more detail information please contact with us